Roof Ventilation in St. Louis

An attic that cannot breathe bakes the shingles in summer and wets the deck in winter. Here is what the code requires, how ridge vents and intake work together, and what poor venting does to a warranty.

  • Code minimum: 1 sq ft of vent per 150
  • Balanced: 40-50% of vent area up high
  • Ridge vent paired with matching eave intake
Free roof inspectionEvery slope photographed. The report is yours either way.

By sending, you agree Arch City Roofers may call, text or email you about your roof. Msg & data rates may apply. Reply STOP to opt out. SMS terms · Privacy

Free roof inspectionEvery slope photographed
Storm & hail claimsWe meet your adjuster on the roof
Written, line-item quotesMaterials named by brand
Both sides of the river45 cities & jurisdictions

Attic ventilation is easy to ignore because none of it shows from the street. It still decides how hot the attic gets in July, whether moisture from the house condenses on the roof deck in January, and whether the shingle maker will stand behind its warranty.

St. Louis puts a roof through both extremes. In NOAA's 1991-2020 normals, Lambert airport averages 47 days a year at 90 degrees or hotter and about 85 nights at or below freezing. This page covers what attic ventilation is for, the code's vent ratios, why intake and exhaust have to balance, what all of it means for ice dams here, why bath fans must vent outdoors, and what shingle warranties say about airflow.

What attic ventilation is for

A vented attic is meant to stay close to the outdoor temperature, with outside air coming in low at the eaves and leaving high at the ridge. ARMA, the asphalt shingle industry's association, gives the reasons in plain terms:

  • Winter moisture. A family of four puts roughly two to four gallons of water vapor into the air each day from breathing, showers, cooking and dishwashing. Warm, damp air rises into the attic, and in a cold attic it condenses on the rafters, the nails and the underside of the deck. Nails corrode, wood rots, and wet insulation can bring on mold.
  • Summer heat. Sun on the roof heats the attic, and without ventilation that heat radiates into the rooms below and keeps the air conditioner running.
  • The roof itself. ARMA says improper ventilation can lead to premature deterioration of shingles and the roof deck, and FORTIFIED, the building program of the research institute IBHS, lists curled or cupped shingles as a possible sign of poor attic ventilation.
  • Ice dams. Warm spots on a snowy roof start the melt that feeds them; more on that below.

Ventilation is one part of a system that also includes air sealing and insulation; the ice dam section below explains the order the Department of Energy puts them in.

What the code requires: the vent ratios

Section R806 of the International Residential Code requires enclosed attics and rafter spaces to be cross-ventilated. St. Louis County's re-roofing checklist spells out the numbers from R806.2:

  • 1 square foot of net free vent area for every 150 square feet of attic floor, as the base rule.
  • 1 for every 300 when the vents are split high and low: 40 to 50 percent of the required area high in the attic, within 3 feet of the ridge, with the balance low at the eaves. The county lists its own added conditions for this lower ratio, so confirm how your city reads it.
  • A clear air space of at least 1 inch between the insulation and the roof sheathing, kept open at the eaves with baffles (R806.3).

"Net free area" is the open area a vent actually passes after its screens and louvers, which the Department of Energy's Building America guidance notes is less than the vent's overall size. Worked through for a 1,500-square-foot attic floor:

RatioNet free area neededWhere it goes
1/15010 sq ft (1,440 sq in)Anywhere that gives cross-ventilation
1/3005 sq ft (720 sq in)288 to 360 sq in up high, the rest at the eaves

On a re-roof, St. Louis County requires the attic ventilation to be checked against R806 and brought into line if it falls short.

Ridge vents need intake to match

A ridge vent is only the exit. ARMA describes a balanced system as one where intake at the eaves equals exhaust at or near the ridge, so air sweeps the whole underside of the deck on its way up.

More exhaust is not better. The Department of Energy's guidance is not to vent the exhaust side more than the intake side. An exhaust that pulls harder than the eaves can supply makes up the difference with conditioned air drawn up from the house through ceiling leaks.

The common mistakes are easy to list:

  • Blocked intake. Soffit vents painted shut or buried under blown-in insulation. ARMA's fix is clearing them and adding baffles.
  • Mixed exhaust. A ridge vent plus gable louvers or a powered fan on the same attic. ARMA advises using only one type of exhaust on a common attic, because a second one can short-circuit the airflow.
  • Gaps in coverage. DOE recommends venting every rafter or truss bay at the intake side.
  • No soffit at all. Some houses have nothing to vent at the eaves. Intake can come from the roof edge instead; Owens Corning's InFlow vent, for one, is sold for soffit-less homes.

On every replacement, we pair the ridge vent with intake to match, as shown in the cut-away on our roof replacement page.

Ice dams and the St. Louis freeze-thaw

Winter here is a cycle more than a season. Lambert's normals show the low dipping to 32 or colder on about 85 days a year, while the high stays at freezing or below on only about 19, so most freezes are followed by a thaw. Snow averages 16.6 inches a year, and the local ground snow load used for design is 20 pounds per square foot (the roofing code guide lists the other design figures).

The Department of Energy's Building America guidance treats ice dams as typical where ground snow loads pass 60 pounds per square foot and likely where they pass 30. By that measure, St. Louis is below the line, and the design tables published locally, in St. Peters and St. Louis County, do not call for an ice barrier at all. When a dam does form here, the house is usually helping it along: heat leaking through light fixtures and exhaust fans, ducts or equipment in the attic, or thin insulation over the outside walls at the eaves.

DOE puts air sealing first, then insulation, then ventilation. For the vents, its guidance is to keep the intake at least equal to the exhaust, vent every bay, and leave 2 inches of air space above the insulation even though the code asks for 1. We still put ice-and-water membrane at the eaves and valleys of every new roof, and the roof repair page covers winter leaks.

Bath fans, dryers and kitchen ducts

Every exhaust fan in the house is supposed to end outdoors. When a bath fan's duct stops in the attic, or lies loose on the insulation, each shower sends a cloud of warm, wet air straight to some of the coldest surfaces in the house: the nails and the underside of the deck.

The rules agree. The Department of Energy's code brief on attic upgrades says bath fans venting into the attic must be changed to vent outside. ARMA tells homeowners to make sure nothing from inside the house discharges into the attic. St. Louis County goes further for re-roofs: its checklist has any duct that ends in an enclosed attic or rafter space extended to discharge outdoors. The one allowance it makes is for bathroom exhaust, which may end at a gable or soffit vent if the duct is secured within 6 inches of it.

Look for these in your attic: flexible duct with an open end, a duct aimed at the soffit but not attached to anything, or a stained patch of deck near where a fan duct ends. Dryer vents and kitchen hoods belong outside for the same reason, and their lint and grease make it worse.

Ventilation and your shingle warranty

Shingle makers treat ventilation as part of the installation, not an option. Owens Corning's current standard limited warranty lists "damage caused by improper or inadequate roof ventilation or roof drainage, unvented attics, or enclosed roof rafter assemblies" among the things it does not cover, and its installation instructions say ventilation must comply with local building codes.

That matters most in three situations:

  • Re-roofing an older house whose vents were never sized to the code, which ARMA says is the time to evaluate the attic.
  • Attics converted to unvented space, such as foam sprayed on the underside of the deck. Read the shingle maker's terms before you choose shingles for that roof.
  • Cathedral ceilings and finished attics, where each rafter bay needs its own path from eave to ridge.

If your next roof is a shingle roof, the roof shingles page compares lines; whichever you pick, the vent plan should be written into the quote.

Signs your attic is under-ventilated

Most of these show up from inside the house or the attic, not from the yard:

  • Winter: frost or droplets on nail tips and the underside of the deck, stains on the deck with no roof leak above them, damp or matted insulation, a musty smell.
  • Summer: upstairs rooms that stay hot in the evening while the air conditioner runs and runs.
  • On the roof: curled or cupped shingles, and ice dams or heavy icicles at the eaves after a snow.
  • At the vents: no daylight visible at the ridge vent from inside the attic, which ARMA uses as a quick check, or soffit vents clogged with paint, dirt or insulation.

Our free roof inspection photographs every vent and penetration along with the slopes. If the attic is the problem, ARMA notes the fix can be as simple as unblocking soffit vents, and any of it is easier to sort out before a re-roof than after one.

Common questions about roof ventilation in St. Louis

How much attic ventilation do I need?

The residential code's base rule is 1 square foot of net free vent area for every 150 square feet of attic floor, or 1 per 300 when the vents are balanced, with 40 to 50 percent of the area high on the roof and the balance at the eaves. For a 1,200-square-foot attic, that is 8 square feet, or 4 with balanced vents.

Can I have a ridge vent and gable vents together?

It is not recommended. The Asphalt Roofing Manufacturers Association advises using only one type of exhaust vent on an attic that shares one air space, because two kinds can short-circuit each other and leave parts of the deck without airflow. If a ridge vent goes on, plan what happens to the old gable or box vents.

Should I add more exhaust vents to cool the attic?

Only if the intake can keep up. The Department of Energy advises against venting the exhaust side more than the intake side, because an exhaust that outpulls the eaves draws conditioned air out of the house through ceiling leaks. Check the eaves before adding anything at the top.

Can my bathroom fan vent into the attic?

No. The Department of Energy's guidance says bath fans that vent into an attic must be changed to vent outside. St. Louis County's checklist for re-roofs has attic ducts run outdoors too, letting bath exhaust end at a gable or soffit vent only when the duct is secured within 6 inches of it.

Does poor ventilation void my shingle warranty?

It can leave you without coverage. The standard warranty Owens Corning issues on its shingles lists damage caused by improper or inadequate roof ventilation, unvented attics and enclosed rafter assemblies among its exclusions. Check the terms for your brand before you choose shingles, especially over a foamed or finished attic.

Will better ventilation stop ice dams?

It helps, but it is not the first step. Department of Energy guidance puts air sealing the ceiling first, then insulation, then ventilation that keeps the roof deck cold. St. Louis gets less snow than the places where ice dams are routine, so a dam here usually points to heat escaping into the attic.

Where we work

Roof ventilation across greater St. Louis, from the city and St. Louis County out to St. Charles, Jefferson and Franklin Counties and across the river into the Metro East. Each city has its own page with the permit rule and code edition that apply there:

Sources: St. Louis County Public Works, Residential Re-Roofing Checklist and Guide (IRC R806, R806.2, R806.3; duct rule) · U.S. DOE Building America Solution Center, Construct Roofs and Attics for Ice Dam Prevention · U.S. DOE Building America Solution Center, Calculating Attic Passive Ventilation (net free area) · U.S. DOE Building America Solution Center, Sealing and Insulating Existing Vented Attics, code brief · Asphalt Roofing Manufacturers Association, Let the Attic Breathe for the Health of the House · Asphalt Roofing Manufacturers Association, Spring Roof Inspection a Must for Property Owners · Asphalt Roofing Manufacturers Association, Reroofing: Replacement vs. Recover · Owens Corning, Standard Product Limited Lifetime Warranty, Pub. 10023873 (ventilation exclusion) · Owens Corning, Duration STORM and FLEX installation instructions (ventilation must meet local code) · Owens Corning, VentSure InFlow intake vent installation instructions (soffit-less homes) · FORTIFIED (IBHS), 8 Ways to Know If You Need a New Roof (curled shingles and ventilation) · NOAA NCEI 1991-2020 climate normals, St. Louis Lambert International Airport (USW00013994) · City of St. Peters, Building Code Guide (ground snow load, ice barrier line). Codes, programs and prices change; confirm the current rule with your city before you rely on it.